NOV 27, 2018 1:00 AM PST

Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy.

Sponsored by: Shimadzu
Speaker

Abstract

DATE: November 27, 2018
TIME: 1:00am PT

High-resolution, accurate-mass (HRAM) mass spectrometers (MS) are a class of MS instrumentation with capability to resolve complex sample matrix and to allow identification of compounds by measuring their accurate masses. In particular, those coupled to liquid chromatograph (HRAM LC/MS) have been used extensively for structural elucidation of unknown compounds primarily in chemical industry (impurity analysis) and biological researches (proteomics, metabolomics, lipidomics), but also increasingly in forensic science, food safety and environmental testing. Given the recent reduction of instrumentational cost, it will not take many more years until HRAM analysis becomes a versatile tool for all industries and researches. 

The key performance attribute underlying all application fields is mass measurement accuracy (MMA) as it affords molecular specificity and reduction of false positive results. MMA is given in the specification of HRAM instruments in parts-per-million (ppm), frequently stating a result of a set of representative measurements e.g. “<1 ppm RMS”. However, this by itself does not convey how repeatably and reproducibly this MMA can be achieved. 

The webinar describes various metrics that are relevant to statistical interpretation of MMA, which explain why mass resolution of 30,000 is more than sufficient for mass measurement at sub-ppm accuracy. Using the Shimadzu LCMS-9030 quadrupole time-of-flight MS, the rationale and strength of instrument stability for consistently achieving sub-ppm MMA has been demonstrated in small molecules.

Learning objectives:

  • Discuss how various parameters affect the accuracy of mass measurement
  • Demonstration of mass drift caused by temperature change
  • Learn how to assess whether a HRAM MS is practically capable of measuring at sub-ppm mass accuracy

Show Resources
You May Also Like
FEB 15, 2023 7:00 AM PST
FEB 15, 2023 7:00 AM PST
Date: February 15, 2023 Time: 7:00am (PST), 10:00pm (EST), 4:00pm (CET) While not all microscopy samples can fluoresce, all can scatter light, and this scattered light can be imaged. This ha...
AUG 24, 2022 7:00 AM PDT
AUG 24, 2022 7:00 AM PDT
Date: August 24, 2022 Time: 7:00am (PDT), 10:00pm (EDT), 4:00pm (CEST) Light field microscopy was first introduced in 2006, and allows users to capture the 4D light field within the microsco...
OCT 13, 2022 9:00 AM +08
OCT 13, 2022 9:00 AM +08
First Broadcast: Date: October 12, 2022 Time: 8:00am PDT, 11:00am EDT Second Broadcast: Date: October 12, 2022 Time: 9:00am SGT The new Embedded CryoSPARC Live, now fully integrated with t...
SEP 28, 2022 9:00 AM PDT
SEP 28, 2022 9:00 AM PDT
Date: September 28, 2022 Time: 9:00am (PDT), 12:00pm (EDT), 6:00pm (CEST) While COVID-19 continues to be the most pressing diagnostic focus for clinical laboratories, HIV remains a serious g...
SEP 13, 2022 8:00 AM PDT
SEP 13, 2022 8:00 AM PDT
Date: September 13, 2022 Time: 8:00am (PDT), 11:00am (EDT), 5:00pm (CEST) Preparedness against pandemic diseases demands rapid-response vaccine technology and ready-to-use analytical methods...
AUG 10, 2022 10:00 AM PDT
AUG 10, 2022 10:00 AM PDT
Date: August 10, 2022 Time: 10:00am PDT, 1:00pm EDT The global pandemic has increased focus and scrutiny on molecular diagnostic assay development, resulting in a need for assays that provid...
NOV 27, 2018 1:00 AM PST

Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy.

Sponsored by: Shimadzu


Show Resources
Loading Comments...
Show Resources