NOV 27, 2018 08:00 AM PST

Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy

SPONSORED BY: Shimadzu
C.E. CREDITS: P.A.C.E. CE | Florida CE
Speakers
  • MS Application Specialist, Analytical & Measuring Instruments Division, Shimadzu Corporation
    Biography
      Ash Toyama has 10 years of proteomics research experience. His areas of expertise include not only proteomics but also quantitative mass spectrometry with particular focus on bioanalysis, metabolomics and endocrinology. At Shimadzu Corporation he played roles in academic research collaborations, application development and specification development of mass spectrometers. Ash holds a Master of Science degree in Biochemistry from University of Cambridge, UK, and was granted a Ph.D. degree in Biological Sciences from University of Tokyo for his research on clinical proteomics.

    Abstract:

    DATE: November 27, 2018
    TIME: 8:00am PST

    High-resolution, accurate-mass (HRAM) mass spectrometers (MS) are a class of MS instrumentation with capability to resolve complex sample matrix and to allow identification of compounds by measuring their accurate masses. In particular, those coupled to liquid chromatograph (HRAM LC/MS) have been used extensively for structural elucidation of unknown compounds primarily in chemical industry (impurity analysis) and biological researches (proteomics, metabolomics, lipidomics), but also increasingly in forensic science, food safety and environmental testing. Given the recent reduction of instrumentational cost, it will not take many more years until HRAM analysis becomes a versatile tool for all industries and researches. 

    The key performance attribute underlying all application fields is mass measurement accuracy (MMA) as it affords molecular specificity and reduction of false positive results. MMA is given in the specification of HRAM instruments in parts-per-million (ppm), frequently stating a result of a set of representative measurements e.g. “<1 ppm RMS”. However, this by itself does not convey how repeatably and reproducibly this MMA can be achieved. 

    The webinar describes various metrics that are relevant to statistical interpretation of MMA, which explain why mass resolution of 30,000 is more than sufficient for mass measurement at sub-ppm accuracy. Using the Shimadzu LCMS-9030 quadrupole time-of-flight MS, the rationale and strength of instrument stability for consistently achieving sub-ppm MMA has been demonstrated in small molecules.

    Learning objectives:

    • Discuss how various parameters affect the accuracy of mass measurement
    • Demonstration of mass drift caused by temperature change
    • Learn how to assess whether a HRAM MS is practically capable of measuring at sub-ppm mass accuracy

    Show Resources
    You May Also Like
    MAY 22, 2018 08:00 AM PDT
    C.E. CREDITS
    MAY 22, 2018 08:00 AM PDT
    DATE: May 22, 2018TIME: 08:00AM PDT The nuclear receptors pregnane X receptor (PXR) and constitutive androstane receptor (CAR) are closely related transcription factors that...
    MAY 24, 2018 09:30 AM PDT
    C.E. CREDITS
    MAY 24, 2018 09:30 AM PDT
    DATE: May 24, 2018 TIME: 9:30PM PDT The current gold standard in in vitro pre-clinical cancer treatment screening remain cell lines,...
    AUG 15, 2018 08:00 AM PDT
    C.E. CREDITS
    AUG 15, 2018 08:00 AM PDT
    DATE: August 15, 2018TIME: 08:00AM PDT, 11:00AM EDTThe failure of current chemotherapeutic strategies in the fight against cancer can be largely attributed to the occurrence of drug res...
    JUN 20, 2018 10:00 AM EDT
    C.E. CREDITS
    JUN 20, 2018 10:00 AM EDT
    DATE: June 20, 2018TIME: 07:00AM PDT, 10:00AM EDTIntroducing GE’s New Lyo-StableTM service. Sepsis is one of the top challenges facing hospitals in terms of clinical outcomes...
    JUN 05, 2018 06:30 AM PDT
    C.E. CREDITS
    JUN 05, 2018 06:30 AM PDT
    DATE: June 5, 2018TIME: 06:30AM PDT, 3:30PM CEST Viscous liquids are a challenge in every lab that deals with them. Depending on how viscous a liquid is, pipetting is either...
    JUN 26, 2018 06:00 AM PDT
    C.E. CREDITS
    JUN 26, 2018 06:00 AM PDT
    Date: June 26, 2018Time: 6:00 a.m. PDT, 9:00 a.m. EDT, 1500 CEST Today’s hematology analyzers employ various methods for enumerating platelets. These methods include: e...
    Loading Comments...